In this applet the operation of a full-bridge DC/DC converter with transformer can be observed. In addition the bi-directional magnetisation of transformer is also shown and the influence that un-symmetric switch pulses has on the transformer’s operation. If there is a un-symmetry in the voltage applied to the transformer then this causes a DC bias. If this is not removed then the transformer will go into saturation. To avoid this, a series capacitor is placed in series with the transformer. A DC voltage then appears on the series capacitor. This problem of DC bias can be safely observed using this applet by removing the series capacitor from the circuit.